Ultraschallfehlerdetektor
-
Ultraschallstärkemessgerät
-
Anstrichschichtdicke-Messgerät
-
tragbare Härteprüfvorrichtung
-
Röntgenstrahlfehlerdetektor
-
Röntgenrohr-Crawler
-
Urlaubsdetektor
-
Magnetpulverprüfung
-
Eddy Current Testing Equipment
-
Durchdringungstests
-
Küstendurometer
-
Brinellhärteprüfvorrichtung
-
Rockwell-Härteprüfvorrichtung
-
Mikro-Vickers-Härte-Prüfvorrichtung
-
Materialhärteprüfer
-
Schwingungsmesser
-
Oberflächenrauheitsprüfer
-
Profilprojektor
-
Glanzmessgeräte
-
konkreter Testhammer
-
Laser-Infrarotthermometer
-
bobAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
WilliamAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
tomAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
-
LeoAstm E114-15 Inch Type 1018 Calibration Test Block Carbon Steel Mini Iiw 2
Digital Concrete Testing Hammer Reinforcement Bar Position Tester

Kontaktieren Sie mich für kostenlose Proben und Gutscheine.
- Was ist?:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
Wenn Sie Bedenken haben, bieten wir 24-Stunden-Online-Hilfe.
xUntersuchungstiefe | 180 mm | Der Durchmesser der Rückenstange (mm) | Φ6-Φ50 |
---|---|---|---|
Abdeckungsdicke Bereich Erster Bereich | 6-90mm | Abdeckungsdicke Bereich zweiter Bereich | 7 bis 180 mm |
Stromquelle Alkaline ZelleX6 | >30 Stunden | ||
Hervorheben | hammer test on concrete,digital concrete test hammer |
Digital Concrete Testing Hammer Reinforcement Bar Position Tester
Features
· investigation depth could reach 180mm
· Single comprehensive probe. No need to replace during test.
· back-lit screen let instrument can be normal used under the condition of insufficient light
· Machine software is complete .The report could be printed automatically connecting with computer
No strong alternating electromagnetic field
No corrosive gas in the air.
Avoid larger vibration and impact
Avoid the LCD panel contact with sunlight directly
Product usage
Testing concrete cover thickness
Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution.
Estimation bar diameter
Detection of Cable and Plumbing pipe
Specifications | |
Rebar diameter range(mm) :Φ6-Φ50 | |
Maximum error of cover thickness +/- 1 | |
Cover thickness range(mm) | |
First range(mm) 6-90 | |
Second range(mm) 7-180 | |
Maximum error of cover thickness | |
First range(mm) Second range(mm) | |
|
|
60-69 80-119 +/- 2 | |
70-90 120-180 +/- 4 | |
Environmental requirement | |
Working temperature℃ -10~40℃ | |
Relative humudity <90% | |
Power source Alkaline cellX6, >30 hours |
Standard Accessories |
1. software disc |
2. manual | |
3. approval certificate | |
4. baldric | |
5. suitcase |