DIN 53505 / ASTM D2240 0 - 100HD Shore Hardness Tester Shore D To Shore A

Herkunftsort Peking
Markenname HUATEC
Zertifizierung ISO, CE, GOST
Modellnummer HT-6510D
Min Bestellmenge 1 Stück
Verpackung Informationen Standardpaket für die Ausfuhr
Lieferzeit 1-4days
Zahlungsbedingungen T/T, PayPal, Western Union
Versorgungsmaterial-Fähigkeit 500 Stück pro Monat

Kontaktieren Sie mich für kostenlose Proben und Gutscheine.

- Was ist?:0086 18588475571

Wechat: 0086 18588475571

Skype: sales10@aixton.com

Wenn Sie Bedenken haben, bieten wir 24-Stunden-Online-Hilfe.

x
Produktdetails
Normen Einheitliche Prüfverfahren für die Bestimmung der Konzentration von Stoffen und Stoffen angezeigte Parameter Härtewert, Durchschnittswert, maximaler Wert
Betriebsbedingungen 0℃ zu 40℃ Stromversorgung 4x1,5 V AAA (UM-4) Batterie
Produktbezeichnung Fläche D Flächenhärte-Meter Schlüsselwort Strandhärteskala d
Hervorheben

astm d2240 shore hardness meter

,

100hd shore hardness meter

,

din 53505 shore d hardness scale

Hinterlass eine Nachricht
Produkt-Beschreibung
Shore D Hardness Scale DIN53505 / ASTMD2240 0 - 100HD Shore D To Shore A Shore Hardness Meter
 
Main application
HUATEC HT-6510D Designed to determine the indentation hardness of materials ranging from cellular products to rigid plastics. Each Durometer type is made to a specific scale (i.e. A, C,D) and is capable of producing a value between 0 and 100. Shore A is designed to measure the penetration hardness of rubber, elastomers and other rubber like substances such as neoprene, silicone, and vinyl. It can also be used for soft plastics,felt, leather and similar materials. Shore C is designed for various foam and sponge.
Shore D is designed for Plastics, Formica,Epoxies and Plexiglass.
 
Special features
* Standards: DIN 53505, ISO 868,ISO 7619, ASTM D 2240, JIS K7215.
* Used the exclusive Micro-computer LSI circuit and crystal time base to offer high accuracy measurement.
* Digital display gives exact reading with no guessing or errors.
* Can communicate with PC for recording, printing and analysing by the optional software and cable for USB and or RS232C interface.
* Automatic power off to conserve power.
* Use operation stand of optional parts can get good accuracy and repetitiveness due

Product synopsis
Product info: Digital durometer for shore hardness testing pocket size model with integrated probe
Test scale: Shore hardness
Standards: DIN53505, ASTMD2240, ISO7619, JISK7215
Parameters displayed: Hardness result, average value, max. Value
Measurement range: 0-100HA(HD)
Measurement deviation: < 1%H
Resolution: 0.1
Auto switch off
With RS232C interface
Operating conditions: 0 to 40
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: Low battery indicator
Dimensions: 162x65x38mm
Weight (not including probe): 173G

Standard accessories:
Main unit
Zero Calibration plate
Carrying case
Instruction Manual
Certificate
 
Optional accessories:
Shore D calibration block kit
Test platform
USB interface with software
Bluetooth with software

Calibration check
To check whether the tester is accurate, just Insert the indenter into the hole of the calibrated test Block. Apply enough force to make firm contact between the top surface of the test block and the presser foot. The reading
should agree with the value stamped on the test block. If not, just carry out Zero calibration and High end calibration.

Zero calibration
Hold the durometer vertically with the point of the indenter hanging in the air, the reading on the display should be '0'. If not, depress the 'ZERO' key to make the tester display '0' .

High end calibration
Just place the indenter onto a flat glass, apply enough force to make firm contact between the glass and the presser foot. The readings on the display should lie between 99.5 and 101. If not, press CAL key to carry out high end calibration.

Battery replacement
When the battery symbol appears on the display, it is time to replace the batteries.
Slide the Battery Cover away from the tester and remove the batteries.
Install batteries paying careful attention to polarity.

NOTE
Readings below 10HD for Shore D type may be inexact and should not be reported for some materials. Measurements should be made on a Shore A type.
Readings above 90HA for Shore A should be made on a Shore D type durometer
 