-
Ultraschallfehlerdetektor
-
Ultraschallstärkemessgerät
-
Anstrichschichtdicke-Messgerät
-
tragbare Härteprüfvorrichtung
-
Röntgenstrahlfehlerdetektor
-
Röntgenrohr-Crawler
-
Urlaubsdetektor
-
Magnetpulverprüfung
-
Eddy Current Testing Equipment
-
Durchdringungstests
-
Küstendurometer
-
Brinellhärteprüfvorrichtung
-
Rockwell-Härteprüfvorrichtung
-
Mikro-Vickers-Härte-Prüfvorrichtung
-
Materialhärteprüfer
-
Schwingungsmesser
-
Oberflächenrauheitsprüfer
-
Profilprojektor
-
Glanzmessgeräte
-
konkreter Testhammer
-
Laser-Infrarotthermometer
-
BobZoll-Art Astm E114-15 Kalibrierungs-Prüfstand-Kohlenstoffstahl 1018 Mini Iiw 2
-
WilhelmZoll-Art Astm E114-15 Kalibrierungs-Prüfstand-Kohlenstoffstahl 1018 Mini Iiw 2
-
TomZoll-Art Astm E114-15 Kalibrierungs-Prüfstand-Kohlenstoffstahl 1018 Mini Iiw 2
-
LöweZoll-Art Astm E114-15 Kalibrierungs-Prüfstand-Kohlenstoffstahl 1018 Mini Iiw 2
Crystal Orientation Indicator X Ray Instrument 30kvp Tube Voltage Copper Target With Anode

Kontaktieren Sie mich für kostenlose Proben und Gutscheine.
- Was ist?:0086 18588475571
Wechat: 0086 18588475571
Skype: sales10@aixton.com
Wenn Sie Bedenken haben, bieten wir 24-Stunden-Online-Hilfe.
xEingangsleistung | Einphasige AC220V、50HZ、0.3 kW | Marke | Huatec |
---|---|---|---|
Rohrspannung | 30KVP, Schalter unter Vollspannung geschlossen | Röhrenstrom | 0 ~ 5 mA, kontinuierlich einstellbar |
Digital-Anzeigen | θ:Grad、Minute、Sekunden; Mindestmesswert von 10′′ | Gegendrehwinkel | 2θ, -10--+120° |
Größe | Der Wert der in Absatz 1 Buchstabe b genannten Verbrennungsmengen beträgt: | Ausrüstungsgewicht | 250kgs |
Hervorheben | crystal orientation indicator x ray instrument,huatec x ray instrument,iso x ray instrument |
30KVP Tube Voltage Copper Target With Anode X-Ray Crystal Orientation Indicator Instrument
HYX-9 model sapphire orientation splice instrument: Mainly used for orientation and splice of sapphire crystal bar which before cutting, it adjusts X-axis and Y-axis of crystal bar by professionally designed clamp, calibrates departure angle of bar then do splice with flitch. Displayer is outer posed type, double working place, also has sample splint with high precision bearing linear rail on it. It can measures 2inch-8inch diameter, 50-140mm length crystal bar.
Technical parameters:
X-ray tube | Copper target with anode grounding, force air cooling. |
Tube voltage | 30KVP, switch closed under full voltage |
Tube current | 0~5mA,continuous adjustable. |
Input power | AC 220V not over 0.3KW |
Integrated precision | ±30″ |
Digital displaying | θ:degree,minute,second; Minimum reading of 10″ |
Counter rotate angle | 2θ, -10--+120° |
Crystal rotate angle | θ-10--+60° |
Counting tube | Geiger tube, voltage of DC700~1200V |
Time constant | 0.1,0.4,3,second; 3levels adjustable |
Protection | HV interlock protection, temperature protection |
Narrow crack | 4′.5′.6′ |
Weight of crystal measuring bar | Crystal bar of 30KG (maximum) |
Diameter of crystal measuring bar | Diameter of Θ2-6inches crystal plate and bar for one surface |
Length of crystal measuring bar | Θ2-4 inches, 260mm crystal bar for the other surface |
Working way | Double angular instrument, double working table |
Outer dimension | 1140X650X1030(mm) |
Equipment weight | 250Kg |